Inspection Data

Should 'A' or 'B' dimensions exceed the given values, the fastener is out-of-grip. A 'C' dimension less than the given value indicates an incomplete swage. A 'D' dimension greater than the given values indicates an incorrect or worn anvil on the installation tool.
 



Dia
A max
B max
C min
D max
12mm
.60
10.6
14.0
18.3
16mm
.60
10.6
17.7
24.1
20mm
.60
10.6
21.2
30.3
 